If the car is equipped, it is recommended to replace the HEPA filter once every 3 years (but annually in China).
Follow these steps to replace the HEPA filter:
- Remove the hood.
- Remove the rear apron from under the hood.
- Both the left and right underhood aprons must be removed.
- Remove the front apron from under the hood.
- Fold the trunk seals back carefully to separate the front of the carpet from the underhood storage unit, then disconnect the electrical link from both underhood storage unit lights.
- Remove the carpet from the storage unit beneath the hood.
- Remove the underhood storage unit's fasteners (x20) from the car.
- Remove the vehicle's underhood storage compartment.
- Remove the old HEPA filter from the duct and discard it.
- Place the new HEPA filter so that it is held in place by the duct.
- Place the underhood storage unit in place and then tighten the fasteners (x2) that secure it:
-
- 6 fasteners (7 Nm)
- 4 fasteners (7 Nm)
- 10 fasteners (4 Nm)
- Put the carpet back into the storage unit under the hood.
- Adjust the seal to prevent ingress by connecting the electrical connectors to the underhood storage unit lights.
- Close the hood after reinstalling the front, left, right, and rear underhood aprons.
Disclaimer:
Tesla, Inc. was not involved in the development of this document and did not provide any input or otherwise edit, review or authorize it.